titrator Automatic titrators
Logout Basket
Check-out Questions about our Titration, High Performance Liquid Chromatography HPLC columns, ERC detectors, Reflective index detectors...
JM Science: Karl Fischer volumetric titrators, Karl Fischer coulometric titrators, High Performance Liquid Chromatography HPLC columns, ERC degassers, ERC detectors, Reflective index detectors...

PRODUCT INFORMATION

AQUACOUNTER Titrators
Potentiometric Titrators
Karl Fischer Titrators
Mercury Analysers


Specifications

   
com1600

COM-1600 Standard Specifications

com1600com1600
Item
Specifications
Titration methods Potentiometric titration, Polarization titration,
Photometric titration, Conductometric titration.
Standard: three inputs of potentiometric titration. (Other titration methods each require a proper measurement probe (option).)
Measurement range pH: 0 to 14 with automatic/manual temperature
compensation
Potential: -2000 to +2000 mV
Temperature: 0 to 100 ßC
End-point detection
method
Learn titration, inflection-point detection, set point detection, inflection-point/set-point detection, cross-point (F, B, V1, V2) detection, dispensing (pH, mL), petroleum product neutrali zation value mode (1, 2), pH measurement, pH Stat, pKa measurement, and calculation.
Number of end-points Learn titration: up to 5 end-points, with linked
CONDITIONs: up to 3 end-points.
Display screen Color graphics liquid crystal display
SAMPLE No. SAMPLE No.: 2 digits, ID code: 16 digits of alphabetical or numerical characters
MASTER files Titration run files: 30
Number of linked CONDITION files: 7 (up to 3 titration files)
CONDITION files Titration parameter files: 30 (Method (For each end point detection), CONSTANT parameter (Concentration calculation constant parameter), Control mode files)
Control mode files Standard files: 30
Petroleum product neutralization value files: 30
Manufacturer preinstalled modes (0 to 19), user defined modes (20 to 29)
SAMPLE files 99 files
(SAMPLE No., ID code, MASTER file and sample amount)
Automatic input function Automatic input of blank, factors, concentration measurement results, etc.
Calculation functions Concentration calculation, statistics calculation, pH automatic compensation
Memory data capacity 100 data (titration results, titration parameters) When memory card (32MB) is used, approximately 1200 data can be stored.
GLP functions Buret precision check, electrode check, buret use frequency, electrode maintenance, remaining reagent volume
Buret Up to 10 burets connected, buret capacity 20 mL (1, 5, 10, and 50 mL are optional.)
Printer interface One port standard
(PR-2000T2, PR-302B or LIPS III-type A4-size printer) Note 1
External
input/output
RS-232C communication port
(for balance input or computer connection)
Expansion bus Expansion bus for full-automatic titration system
Power requirements 100 V to 240 V AC, 50/60 Hz, 60 VA
Dimensions 220 mm (W) x 400 mm (D) x 200 (H) mm
Mass Approx. 5.0 kg
Attached electrodes · GR-101B Glass combination electrode
· RE-201 Reference electrode
com1600
  Note 1: Some A4-size printers cannot be connected to this equipment.
Please contact us and inquire.
 

com1600

B-2000-20 Standard Specifications

com1600com1600
Item
Specifications
Buret capacity
Standard: 20 mL, clear cylinder (with ultraviolet
interception protective cover) The buret heads of 1, 5, 10, and 50 mL are exchangeable (option).
Fabrication 5, 10, 20, and 50 mL: The inner cylinder is fabricated through precision grinding.
1 mL: The outer cylinder is fabricated through precision grinding 1 and 50 mL cylinders are brown.
5, 10, and 20 mL cylinders are clear (with ultraviolet interception protective cover)
Wet path material Teflon, hard glass, and ceramic
Connection tube com16002 x com16003 mm, brown Teflon tube
Reagent bottle Brown glass bottle, 1 L
Selector valve
Automatic selection by way of a ground ceramic joint
Dispensing rate
(full capacity)
50 to 250 seconds, specified by 50 second step (for 20 mL buret)
Smallest volume of
titrant
0.00125 mL when a 20 mL buret is used
Buret precision Accuracy: within ±0.1 %
(for full discharge of 20 mL buret)
Repeatability: within 0.01 mL (for full discharge of 20 mL buret, standard deviation for n = 5)
Power requirements 100 V to 240 V AC, 50/60 Hz, 50 VA
Dimensions 122 mm (W) x 280 mm (D) x 475 (H) mm
Mass Approx. 7.0 kg
com1600

com1600

K-2000T2 Standard Specifications

com1600com1600
Item
Specifications
Number of the equip ment to an electrode holder Electrode (cap sizecom160016 mm) ; 2 places
Thermistor electrode (cap sizecom160010 mm) ; 1 place
Buret tip ; 3 places
Dispenser tip ; 1 place
Beaker Up to 500 mL
Stirring method With the aid of a magnetic flea
Stirring piece Teflon (com16008 x 30 mm, 1 piece supplied)
Power requirements DC 12V (supplied from COM-1600)
Dimensions 110 mm (W) x 210 mm (D) x 350 (H) mm
Mass Approx. 1.0 kg
com1600

com1600

S-2000 Standard Specifications

com1600com1600
Item
Specifications
Number of inputs
Inputs for potentiometric titration: 3, input for
temperature compensation: 1
Detection range pH: 0 to 14 pH (automatic/manual temperature compensation), Potential: -2000 to +2000 mV, Temperature: 0 to 100com1600
Power requirements DC 12V (supplied from COM-1600)
Dimensions 50 mm (W) x 80 mm (D) x 125 (H) mm
Mass Approx. 0.3 kg
com1600

com1600

PR-2000T2 Standard Specifications

com1600com1600
Item Specifications
Printing method/paper Thermal head type, thermal roll paper
(chart width: 80 mm)
Power requirements 100 V to 240 V AC, 50/60 Hz (with AC adapter)
Dimensions 119 mm (W) x 174 mm (D) x 77 (H) mm
Mass Approx. 0.5 kg (printer main unit only)
com1600
To order titrators, related equipment, parts or accesories, please call, fax or email:
  • Phone North America 1-800-495-1678
  • Phone International 1-716-774-8706
  • Fax 1-716-774-8708
  • john@jmscience.com
 
 
Contact JM Science: Distributor of Karl Fischer titrators, ERC degassers, Reflective index detectors, Asahipak, Shodex, Hitachi, Cosmosil, CapcellPak HPLC columns...
Products What's New Specials Technical Support Corporate Info