COM-1600 Potentiometric Titrator

com1600 This very flexible potentiometric titrator features a large color graphics liquid crystal display yet is compact and very easy to use. GLP functions enhance the storage and processing of results while reducing operating costs. This unit can process large numbers of samples when configured with the automation option.
pl
pl

com1600

Features

com1600
  • Color liquid crystal display that is easy to see and understand is provided.
    Large sized Color Graphics LCD is provided to display real-time titration curves and differential curves to show reaction tendencies, etc. All information is easily viewed.

  • Titration with a small amount of sample is possible thus reducing analysis costs and waste. (Optional)
    Measurement with a 1/2 sample volume is possible by using sample vessels and electrode holders that are designed for small amounts of samples. The reagent amount to be used and the waste solution volume after measurement can be greatly reduced saving time and money.

  • GLP correspondent functions to support reliability of the titration results are provided.
    For instance, Buret precision tests and electrode sensitivity measurements that add to the reliability of the titration results. Useful functions for maintenance such as electrode information display, reagent remaining volume indication etc. are also provided.

  • Result storing function to memory cards is provided. Large numbers of data points can be stored.
    The titration results and titration conditions including titration/ differential curve data can be stored in the Smart Media(TM) to perform recalculation and redetection. Reading, recalculation and redetection of titration results, use of data by using other application software is possible by providing the card reading software for a PC or laptop. Data can also easily be downloaded to a laptop or PC for storage or processing using free download software.

  • This titrator can be used as an automatic titration station for multitasking applications.
com1600
pagetop

 
com1600

Options

 
  • Various measurement units for titration

    Photometric Titration, Polarization Titration, Conductmetric Titration are possible by using the appropriate measurement probe.
 
com1600com1600
Model
Uses Specifications
S-2000


For Potentiometric Titration
Neutralization titration, Oxidation reduction titration, Deposition titration, Non- aqueous titration
3 inputs(mV, mV, pH(mV))
0~14 pH, ±2000 mV, 0~100 com1600
M-2000 For Photometric Titration
Chelatometric titration, Neutralization titration, Oxidation reduction titration, Deposition titration, Non-aqueous titration
3 input(T%(Abs), pH(mV), mV) 0~100 T%, 0~14 pH, ±2000 mV, 0~100 com1600
Detection:
Optical Probe designed for liquids.
Interference filter wavelength:
530 nm, 650 nm
P-2000 For Polarization Titration
Amperometric titration, Neutralization titration, Oxidation reduction titration, Deposition titration, Non-aqueous titration
3 inputs(mV(com1600A), pH(mV), mV) ±200 com1600A, 0~14 pH, ±2000 mV, 0~100 com1600
Polarization voltage:0~1 V
Polarization electric current:
1~5 com1600A(5 steps of reshuffling)*1
Attached electrode:
TPT-351 Twin platinum electrode
E-2000

For Conductometric Titration
Conductometric titration, Neutralization titration, Oxidation reduction titration, Deposition titration

3 inputs(com1600S, pH(mV), mV)
0~14 pH, ±2000 mV, 0~100 com1600
0~200, 2000, 20000com1600S(3range reshuffling)*1
Attached electrode:
TPT-351 Twin platinum electrode
com1600
  *1: A displayed unit becomes g.

 
 

COM-1600ST Potentiometric Titrator

COM-1600ST
COM-1600ST

Add a Model C-2010 Automatic Cycler and automate repetitive testing.

When using the Automatic Cycler, pH calibration can be performed automatically too. Reliability measurements can be carried out efficiently.

  • Totally compatible with various ASTM methods including ASTM D664, Standard Test Method for Acid Number of Petroleum Products by Potentiometric Titration.
  • Fully programmable Titration Sequence; Determination of End Point pH using Stock Buffer Solution can also be automated.
  • Electrode preparation between tests is performed in the washing station automatically.
  • Environmentally configured; separate collection of electrode washing solvent and waste water

Click here to View COM-1600ST Slideshow

COM-1600ST
 
com1600com1600
* FOR GMP compliant installation and SOP, please contact JM Science Inc.
* The product color may vary from the actual product due to printing qualities.
* Appearance, specification, etc. are subject to change for improvement without prior notice.
 
To order titrators, related equipment, parts or accesories, please call, fax or email:
  • Phone North America 1-800-495-1678
  • Phone International 1-716-774-8706
  • Fax 1-716-774-8708
  • john@jmscience.com
 

Hitachi lab parts, Hitachi replacement lab parts

About our titration products, HPLC instruments, HPLC equipment

Contact JM Science: Supplier of Karl Fischer titration, Hitachi lab parts, High Performance Liquid Chromatography HPLC columns...
Contact JM Science: Distributor of Karl Fischer titrators, ERC degassers, Reflective index detectors, Asahipak, Shodex, Hitachi, Cosmosil, CapcellPak HPLC columns...
Products What's New Specials Technical Support Corporate Info