titrator Automatic titrators
Logout Basket
Check-out Questions about our Titration, High Performance Liquid Chromatography HPLC columns, ERC detectors, Reflective index detectors...
JM Science: Karl Fischer volumetric titrators, Karl Fischer coulometric titrators, High Performance Liquid Chromatography HPLC columns, ERC degassers, ERC detectors, Reflective index detectors...

Product Categories: Analytical/Bioanalytical

JM Science: Karl Fischer coulometric titration lab products, Karl Fischer volumetric titration lab products...
View Karl Fisher Systems & Accessories
in MS WORD format

AQUACOUNTER® Karl Fischer Volumetric & Coulometric Titration Instruments

Karl Fischer Titrators are hardly new to North America, having been sold here for the last 20 years. Manufactured in Japan by the Hiranuma Company, Karl Fischer volumetric titrators, coulometric titrators and titration instruments represent the highest standards of performance and quality by which all other titrators are measured. Hiranuma manufactured its first potentiometric titrator in 1965 and continues to offer innovative coulometric and volumetric titrator products for testing moisture on the production line, acceptance testing of raw materials, or developing new products in the R&D lab. Hiranuma's AQV-2100S, the AQ-2100S Coulometric Titrator , and the AQV-2100C Combination Volumetric-Coulometric Titrator all display real-time curves for monitoring the progress of any titration. Easily visualize your results while they are occurring on a large, easy-to-view, backlit liquid crystal display. Store up to 50 results, including data points as well as titration curves in the instrument's memory. No more lost data! Simply retrieve and print out data anytime they are required.

The AQV-2100C Volumetric-Coulometric Titrator has two channels available for both coulometric titrations and volumetric titrations. For those who need single channel instruments now, but may need two channels in the future, the AQV-2100S and the AQ-2100S Karl Fischer titrators are capable of expanding to accommodate your future needs with a factory-installed conversion kit. Similarly, the AQV-2100S, which is a single channel volumetric titrator, can be easily converted to either a dual channel volumetric, or combination volumetric-coulometric titrator. Other combinations are possible; please inquire with your needs.

JM Science's new AQUACOUNTER Karl Fischer instruments offer state-of-the-art performance, with unprecedented adaptability, simplicity and accuracy. Our new low cost titrators, the AQ-300 and the AQV-300 offer the same specifications as the 2100 series but are available at very special low pricing. All AQUACOUNTER titrators are covered by a comprehensive warranty and come with demo Karl Fischer reagent kits formulated to work beautifully with our line of titrators or any others.

Volumetric Karl Fischer Titrator

AQV-2100S
JM Science: AQUACOUNTER Karl Fischer coulometric titrators, Karl Fischer volumetric titrators...
  • Multi-channel Capability
  • Large Back Lit LCD Display
  • Real Time Titration and Background Curves
  • GLP/ISO Compatibility
  • Automatic Control of Evaporator
  • Storage for 50 Results

This dependable workhorse has an extremely wide measuring range... From ppm to 100%, its automatic background compensation function allows accurate volumetric measurements of trace moisture levels. The unit has a 10ml single buret, a single stirrer, and a single volumetric cell. The AQV-2000S can also be converted to either a two channel volumetric titrator or a two channel volumetric-coulometric titrator. The volumetric conversion allows the use of two different strength titrants for maximum analytical flexibility.

AQUACOUNTER® AQV-2100S Volumetric Titrator Specifications
Item Specifications
Titration Method Volumetric titration with Karl Fischer reagent
Titration control method Intermittent titrant addition while approaching the end point.
(1)Wait-time (INTERVAL) controlled; duration from 1-99sec
(2)Titration-time (T-TIMER) controlled; duration from1 second to 99 minutes
Background correction Automatic correction can be enabled/disabled.
Buret Capacity; 10 ml, reproducibility; ±0.01 ml
(for full discharge, standard deviation for n=5)
Accuracy: within-:4.1 5% (for full discharge,n=5)
Tubing Teflon tube of 2 mm (ID) and 3 mm (OD)
Accuracy Within CV of 0.3
With water-methanol (1mg H2O/mL),Ig is measured 10times.
Valve selection Automatic selection with ceramic joint valve
Number of burets 1; (expandable to 2)
Measurement range 0.1 mgH2O- 500mgH2O
Minimum volume of addition 0.005 ml or 0.01 ml
Minimum volume of addition 0.005 ml or 0.01 ml
Titration cell capacity 150 ml, minimum volume of consumption; about 30 ml
Display screen Graphic liquid crystal display
Display units ml, mgH2O, %, and ppm (min. display is 0.001 ml.)
Calculation functions Concentration, factor standardization, and statistics
Method files Titration parameter files; 20
Sample file; 1 (number of reserved samples = 99)
EV file : 20
Memory data capacity 50 data points/channel
Printer interface One port standard
External input/ output RS-232C; 2 ports
Port 1 (HOST)_/index.html command instructions from host computer
(Port 1 is used for output to the host computer or for theheating vaporization device connection.)
Port 2 (BALANCE)_/index.htmldata input from a balance or data outputto a host computer.)
Power supply 100-240 V AC, 100 VA
Dimensions 220 (W), 400 (D), and 330 mm (H)
Weight About 7 kg (Stirrer and printer not included.)

Top

Volumetric/Coulometric Karl Fischer Titrator

AQV-2100C
JM Science: Coulometric Karl Fischer titration lab products, volumetric Karl Fischer titration lab products.
  • Dual titration capability of this extraordinary tool performs the widest range of Karl Fischer applications without exception.
  • Menu-driven system makes it easy to program and perform all operations.
  • Large LCD viewing area shows a wealth of information and makes real time curves easy to read.

The AQV-2100C provides the flexibility you need to perform titrations on a wide range of samples regardless of their water content. From a few ppm all the way to 100%, you'll have all the analytical capability you need right on your benchtop. Whether you're performing a coulometric titration on a lyophilized protein or a volumetric titration on cosmetics, you'll be able to count on fast, accurate results.


Top

Coulometric Karl Fischer Titrator

AQ-2100S
JM Science: Karl Fischer volumetric titration lab products, Karl Fischer coulometric titration lab products...
  • New options allow generation of detailed titration curves, even for one minute titrations.
  • Increased coulometric-current range reduces blanking time up to 50%.
  • Innovative cell design decreases maintenance over the life of the cell.
  • Replaceable membrane combines the superior precision of a ceramic frit with the ease-of-maintenance of a fritless system.
  • Convenient, quick, and safe electrode cable attachment.
  • Optional Fritless Cell.

The AQ-2100S is our standard coulometric titrator. This unit consists of one stirrer and one coulometric cell, and is the logical choice for most trace moisture applications. An optional coulometric kit is available that will convert the unit to a two-channel coulometric titrator. With the addition of this kit, you'll be able to quickly and efficiently run both routine samples and those problematic samples that require special reagents (e.g., aldehydes and ketones).

AQUACOUNTER® AQ-2100S Coulometric Titrator Specifications
Item Specifications
Titration Method Coulometric titration process
Electrolytic control method Constant current electrolysis, intermittent electrolysisin the vicinity of the end point only.
Titration control method AC polarization potential difference detection method
(1)Wait-time (INTERVAL) controlled; duration from 1-99 sec
(2)Titration-time (T-TIMER) controlled; duration from1 second to 99 minutes
Automatic conpensation
Range for background
0 - 50 µg H2O/min.
Measuring range 10 µg H2O - 99 mg H2O
Accuracy Within CV of 0.3
With water-methanol (1mg H2O/mL),Ig is measured 10times.
Required measuring time FAST 33 sec/mg H2O
MEDIUM 50 sec/mg H2O
SLOW 100 sec/mg H2O
Titration cell capacity 150 ml.
Display screen Graphic liquid crystal display.
Display units ug H2O, %, and ppm (least amount of display is 0.1 ug)
Calculation functions Concentration and statistics
Method files Titration parameter files; 20
Sample file; 1 (number of reserved samples = 99)
EV file : 20
Memory data capacity 50 data points/channel
Printer interface One port standard
External input/output RS-232C; 2 ports
Port 1 (HOST)_/index.html command instructions from host computer
(Port 1 is used for data output to the host computer or forthe heating vaporization device connection.)
Port 2 (BALANCE)_/index.html data input from a balance or data outputto host computer.
Power supply 100-240 V AC, 100 VA
Dimensions 220 (W), 400 (D), and 200 mm (H)
Weight About 4.5 kg (Stirrer and printer not included.)

Top

New AQUACOUNTER® AQV-300 Low Cost Volumetric Karl Fischer Titrator

On a tight budget and looking for a reliable, easy-to-use volumetric Karl Fischer titrator?
Then look no further than the AQUACOUNTER® AQV-300. State-ofthe-art performance features let you measure moisture content from low to high concentrations quickly and accurately.
Measurements are simple and routine with unsurpassed precision.

AQUACOUNTER® AQV-300 Advantages
  • Six (6) built-in calculation modes accommodate solid, liquid and gas samples.
  • One-touch calculations including a statistics package!
  • Four (4) files with preset conditions can be stored in memory
  • Balance and computer interfaces for GLP and ISO documentation.
  • Instant recall of data for up to 20 samples.
  • Built-in detector monitors titration status.
  • Compact unit with small footprint
  • Choice of thermal printer or impact printer.
  • Direct key access allows entry of titration parameters
  • Very competitive price

 

AQUACOUNTER® AQV-300 Standard Specifications
Item Specifications
Titration Method Volumetric Karl Fischer titration method
Titration control method Intermittent addition of titrant while approaching the end point.
(1) Control by waiting interval timer of 1-99 sec (INTERVAL).Titration stops when there is no change in the electrode potential during this interval.
(2) Control by titration timer (T-TIMER: 1-99 min.)
End point detection DC polarization potential difference detection.
Buret capacity 10 ml
Valve selection Automatic selection with ceramic joint valve
Number of burets 1
Display screen Graphic liquid crystal display
Display units 2 lines by 32 digits with backlit LCD
Display units ml, mg H2O, %, or ppm (display minimum=0.01 ml)
Measuring range 100 ppm - 100%
Minimum volume of addition 0.01 ml
Calculation function Concentration, factor standardization
Titration cell capacity 150 ml
Minimum volume of consumption Approx. 30 ml
External input/output RS-232C; 2 ports
Port 1 (HOST) Command instructions from host computer
Port 2 (BALANCE) Data input from balance or data input
Dimensions 310 mm wide x 270 mm deep x 300 mm high
Printers Optional thermal printer: Seiko DPU-414
Optional impact printer: Citizen CBM-910
Power supply ; Power consumption AC 100-240 V, 50/60 Hz & 100VA
Weight 6 Kg

Top

New AQUACOUNTER® AQ-300 Low Cost Coulometric Karl Fischer Titrator

Are you on a tight budget and looking for a reliable, easy-to-use coulometric Karl Fischer titrator?
Then look no further than the AQUACOUNTER® AQ-300. With state-of-the-art performance features like a fritless cell option, the AQ-300 offers the same fast and accurate results you've come to expect from other Hiranuma titrator products.

AQUACOUNTER® AQ-300 Advantages
  • Six (6) built-in calculation modes accommodate solid, liquid and gas samples
  • One-touch calculations including a statistics package!
  • Four (4) files with preset conditions can be stored in memory
  • Balance and computer interfaces for GLP and ISO documentation
  • Instant recall of data for up to 20 samples
  • Built-in detector monitors titration status
  • Choice of ion exchange or fritless cell system
  • Choice of thermal printer or impact printer
  • Printout Contents: date, sample number, measurement value (ugH2O),sample quantity, moisture content, mean value, standard deviation, CV, moisture quantity-time curve, other preset titration parameters
AQUACOUNTER® AQ-300 Standard Specifications
Item Specifications
Titration Method Coulometric Karl Fischer titration method
Electrolytic control method Constant current electrolysis, intermittent electrolysisin the vicinity of the end point only
Titration control method AC polarization potential difference detection method
(1) Automatic stop at endpoint after elapsedINTERVAL time (INTERVAL: Max. 99 sec.)
(2) Titration time setting system (T-TIMER: Max. 99 min.)
Automatic background compensation range - 50 µg H2O/min.
Display screen 2-lines by 32 digits with backlit LCD
Display unit pg H2O, %, ppm
Detection sensitivity 0.1 pg H2O
Accuracy +/- 1µg H2O during 10-1,000.tg H2O measurements (whensampling more than 1 g of H2O- methanol standard)
+/- CV of 0.3 % during 1 - 30 mg H2O measurement (for standardcell)
Measuring range 10 pg H2O - 99 mg H2O
Required measuring time FAST 50 sec/mg H2O
Titration cell capacity 150 ml
Input of parameter settings With key pad
File function 4 files for titration parameters
External input/output Balance, Printer and RS232C data output
Dimensions 310 mm wide x 270 mm deep x 300 mm high
Printers Optional thermal printer: Seiko DPU-414
Optional impact printer: Citizen CBM-910
Alarm 5 sec alarm when titration ends
Power supply ; Power consumption AC 100-240 V, 50/60 Hz & 100VA
Weight 5 Kg

Top

AQS-2010 VOLUMETRIC

JM Science: Karl Fischer coulometric titration lab products, Karl Fischer volumetric titration lab products.

Automated Evaporation KF Titration System AQS-2010 (Automated Evaporator/Sample Changer EV-2010)

For medium to heavy workloads
Up to 10 samples can be mounted on the turntable at the same time. Up to 99 samples can be run by simply removing the finished sample and adding a new one.

Extremely compact design

A compact upright design for both the heating block and the KF titrator saves your valuable bench space.

Wide temperature range and programmable temperature control
The heating temperature can be set up to 30° C and programmed up to 3 steps.
This feature makes it easier to find the optimum temperature for each individual sample, or allows you to differentiate surface water from bound water.

Integrated Air Pump
Compact, integrated air pump (Optional) eliminates the need for nitrogen carrier gas.

Incorporate both coulometric and volumetric titrator
The EV-2010 automated evaporator/sample changer can be connected with both the AQ-2100 coulometric titrator and the AQV-2100 volumetric titrator, which makes the AQS-2010 a complete automated evaporation KF titration system. For the best accuracy for determining trace level of water, AQ-2100 coulometric titrator is recommended.

Technical Specifications for the EV-2010
Number of sample vials: 10
Volume of sample vial: 10 ml
Seal:
Carrier gas:
Carrier gas flow rate:
PTFE cap with aluminium foil
Nitrogen or Dry air (Optional)
30 - 300 ml/min
Carrier gas desiccant:
Heater:
Heating block material:
Temperature range:
Power:
Molecular Sieves
Band heater
Aluminium
RT to 300°
100-240 V AC 50/60Hz 250VA
Dimension: 260W x 600D x 280W (mm)
Weight: 11 kg

Top

Evaporators

AQUACOUNTER® EV-2000 Solid Evaporator

JM Science: AQUACOUNTER Karl Fischer coulometric titrators, Karl Fischer volumetric titrators, solid evaporators...

For samples that cannot be conveniently tested by direct titration , JM Science offers two evaporator models...
One designed for solids and one designed for grease, oils and other difficult samples. Both are fully-compatible with our AQUACOUNTER® Karl Fischer titrators and are extremely valuable in analyzing difficult samples.

In concert with the AQ-2100S, the AQV-2100S and the AQV-2100C titrators, the EV-2000 Solid Evaporator uses up to three different temperatures during the titration. Surface moisture can now be differentiated from bound moisture.

EV-2000 Standard Specifications
Item Specifications
Temperature control Settable, automatic temperature control.
Heating range (Room temperature)-350 °C Overheat protection by thermostat.
Carrier gas
Flow rate
N2 gas or dry air
0.1-0.5 L/min (settable)
Carrier gas input pressure 0.8 MPa or less
Carrier gas desiccant Molecular sieves 100 g
Heater Band heater
Sample volume About 10 mL or less
Measurement range Conforms to specifications for water content measurement instrument
Power requirements 100 V -240 V, AC 50/60 Hz, 150 VA, CE Mark
Size 220 (W) x 430 (D) x 200 (H) mm
Weight About 8 kg

Top

AQUACOUNTER® EV-2000L Oil Evaporator

JM Science: Coulometric Karl Fischer titration lab products, volumetric Karl Fischer titration lab products, oil evaporators...

The EV-2000L Oil Evaporator utilizes azeotropic distillation (Miniature Dean & Stark Distillation). It determines moisture in oils quickly and efficiently by direct titration of vapors produced by distillation of the solvent and the sample. This evaporator can be used with any Karl Fischer titrator, regardless of manufacturer.

Item Specifications
Evaporation method Indirect draft azeotropic distillation method (With N2 gas ordry air).
Temperature adjustment Selectable, automatic temperature adjustment.
Carrier gas N2 gas or dry air. Flow rate : 30-300 mL/min (settable)
Carrier gas inlet pressure 0.8 MPa or less
Carrier gas desiccant Molecular Sieves 100 g
Heater About 100 VA, band heater, room temp-2000
Sample volume About 10 mL or less
Measurement range The same as that of water content measurementinstrument.
Solvent Benzene, toluene, Xylene, etc.Volume for one measurement : 5-10 mL.
Power source 100-240 V, AC 50/60 Hz, 150VA., CE Mark
Size 220 (W) x 340 (D) x265 (H) mm
Weight About 7 kg

Top

Ordering Information
AQUACOUNTER® Instrument Part Numbers

Part numbers for Karl Fischer Titrator System
Model Description Part No.
Coulometric Karl Fischer titrators
AQ-300 Lower Price coulometric titrator w/integrated stirrer D310081-A
AQ-2100S Coulometric titrator AQ-2100 w/ Stirrer K-2000A D310045-A
AQ-2100SP Coulometric titrator AQ-2100 w/ Pump/Stirrer K 2000AP D310046-A
2 channel coulometric Karl Fischer titrators
AQ-2100C Coulometric titrator AQ-2100 w/ Stirrer K -2000A, and Additional coulometric channel and stirrer D310047-A
AQ-2100CP Coulometric titrator AQ-2100 w/ Pump/Stirrer K-2000AP, and Additional coulometric channel and stirrer D310048-A
Volumetric Karl Fischer titrators
AQV-300 Lower price volumetric titrator w/integrated stirrer D320084-A
AQV-2100S Volumetric titrator AQV-2100w/ Stirrer K-2000A D310050-A
AQV-2100SP Volumetric titrator AQV-2100w/ Pump/S tirer K 2000AP D310051-A
2 channel Volumetric and Coulometric Karl Fischer titrators
AQV-2100C Volumetric titrator AQV-2100 w/ Stirrer K -2000A, Additional coulometric channel and stirrer D310052-A
AQV-2100CP Volumetric titrator AQV-2100 w/ Pump/Stirrer K-2000AP, and Additional coulometric channel and stirrer D310053-A
2 channel Volumetric Karl Fischer Titrators
AQV-2100V Volumetric titrator AQV-2100 w/ Stirrer K-2000A, Additional volumetric channel and stirrer D310054-A
AQV-2100VP Volumetric titrator AQV-2100 w/ Pump/Stirrer K-2000AP, and Additional volumetric channel and stirrer D310055-A
Twin buret Volumetric Karl Fischer Titirators
AQV-2100B Volumetric titrator AQV-2100 w/ Stirrer K-2000A, and additional buret B130-10 D310056-A
AQV-2100BP Volumetric titrator AQV-2100 w/ Pump/Stirrer K-2000AP, and additional buret B-130-10 D310057-A
Automated Solid Evaporator/Karl Fischer Titrator Systems
AQS-2010S Coulometric titrator AQ-2100S w/Automated solid evaporator/Sample changer EV-2010 D330051-A
AQS-201OVS Volumetric titrator AQV-2100S w/Automated solid evaporator/Sample changer EV-2010 D330052-A
Constituent Units
AQ-2100 Coulometric titrator AQ-2100 main unit D310111-A
AQV-2100 Volumetric titrator AQV-2100 main unit D310211-A
EV-2000 Solid evaporator for AQ/AQV-2100 series(For AQ/AQV-300, additional key-pad is required) D310158-A
EV-2000L Oil evaporator for all titrators D310168-A
EV-2010 Automated Solid evaporator/Sample changer for AQ/AQV-2100 series D310172-A
K-2000A Stirrer for AQ/AQV-2000 series D310117-A
K-2000AP Stirrer w/ pump for solvent addition and waste disposal D310119-A
B-130-10 Additional buret w/ 10 ml cylinder D310248-A
Printers
Thermal printer for AQ/AQV-300 Model DPU-414-30B w/ Cable KPU-101 D310250-A
Thermal printer for AQ/AQV-300 Model PRINTY 3 w/ Cable KPU-101 D310253-A
Impact printer for AQ/AQV-300 Model CBM-910-40PF w/ Cable KPU-101 D310254-A
Thermal printer for AQ/AQV-300 Model DPU-414-30B w/ Cable CPC-F2 D310252-A
Thermal printer for AQ/AQV-300 Model PRINTY 3 w/ Cable CPC-F2 D310251-A
Impact printer for AQ/AQV-2100 Model CBM-910-40PFw/ Cable CPC-F2 D310255-A

Top

Get a free volumetric or coulometric reagent kit with your purchase of any AQUACOUNTER® titrator. Simply make a purchase of any KF titrator get yours absolutely free.

JM SCIENCE INC
355 Lang Blvd. PO Box 250
Grand Island, NY 14072
Phone: 716-774-8706
Fax: 716-774-8708
Email: john@jmscience.com


Hitachi lab parts, Hitachi replacement lab parts

About our titration products, HPLC instruments, HPLC equipment

Contact JM Science: Supplier of Karl Fischer titration, Hitachi lab parts, High Performance Liquid Chromatography HPLC columns...
Contact JM Science: Distributor of Karl Fischer titrators, ERC degassers, Reflective index detectors, Asahipak, Shodex, Hitachi, Cosmosil, CapcellPak HPLC columns...
Products What's New Specials Technical Support Corporate Info