AQUACOUNTER AQ-2100 Series Karl Fischer Coulometric Titrator
 |
1. Solid Evaporator EV-2000 |
| |
 |
The EV-2000 is designed for solid samples which are not soluble in the Karl Fischer reagent or contains interfering substances. EV-2000 works with our AQUACOUNTER Karl Fischer titrator series and can be automatically controlled from the AQ-2100 or AQV-2100 titrator. |
|
| |
EV-2000 Standard Specifications |
|
 |
| Heating Temperature |
Room temperature to 350 |
| Carrier gas |
N2 gas or dry air |
| Carrier gas flow rate |
0.1 - 0.5 L/min |
| Carrier gas input pressure |
0.8MPa or less |
| Carrier gas desiccant |
Molecular sieves |
| Heater |
Aluminium block heater |
| Sample volume |
About 10mL or less |
| Power supply, Power consumption |
AC100V - 240V, 50/60Hz, 150VA |
| Dimensions, Weight |
220 (W) x 430 (D) x 200 (H) mm, about 8kg |
|
|
 |
 |
2. Oil Evaporator EV-2000L |
| |
 |
The EV-2000L Oil Evaporator
utilizes azeotropic distillation (Micro Dean & Stark Distillation).
It completely separates water from sample matrices, thus eliminating any
side reactions with interfering substances. The EV-2000L can be used
with AQUACOUNTER Karl Fischer titrators, or any other manufacturer's
titrators. |
|
| |
EV-2000L Standard Specifications |
|
 |
| Evaporation method |
Azeotropic distillation
method |
| Heating range |
Room temperature to 200 |
| Carrier gas |
N2 gas
or dry air |
| Carrier gas flow rate |
30 - 300mL/min |
| Carrier gas
inlet pressure |
0.8 MPa or
less |
| Carrier gas desiccant |
Molecular Sieves |
| Heater, Heating block
material |
Aluminium block heater |
| Sample volume |
About 10ml or less |
| Measurement range |
The same as that of the connected titrator. |
| Azeotropic Solvent |
Benzene, toluene, Xylene,
etc.
Volume for one measurement; 5-10mL. |
| Power supply, Power consumption |
100 V - 240 V, AC 50/60
Hz, 150 VA. |
| Dimensions, Weight |
220 (W) x340 (D) x 265
(H) mm, about 7kg |
|
 |
 |
3. Automated Solid Evaporator EV-2010 |
| |
 |
The EV-2010 automated
evaporator/sample changer can be connected with both AQ-2100 coulometric
titrator and AQV-2100 volumetric titrator, which makes the AQS-2110
a complete, automated evaporation KF titration system. |
|
| |
- For medium to heavy workloads
Up to 10 samples can be placed on the turntable at the same
time. Up to 99 samples can be run by simply removing the finished
sample and adding a new one.
- Extremely compact design
A compact upright design for both the heating block and
the KF titrator saves valuable bench space.
- Wide temperature range and programmable
temperature control
The heating temperature can be set up to 300 and programmed up to 3 steps.
This feature makes it easier to find the optimum temperature
for each individual sample, or allows you to differentiate surface
water from bound water.
- Dry Air Pump (Optional)
Compact, integrated air pump eliminates the need for nitrogen
carrier gas.
|
|
| |
EV-2010
Standard Specifications |
|
 |
| ITEM |
SPECIFICATIONS |
| Number of sample vials |
10 |
| Volume of sample
vial |
10mL |
| Seal |
PTFE cap with aluminium
foil |
| Carrier
gas |
Nitrogen
or Dry air (Optional) |
| Carrier gas flow
rate |
30 - 300mL/min |
| Carrier gas desiccant |
Molecular Sieves |
| Heater, Heating
block material |
Aluminium block
heater |
| Heating range |
Room temperature
to 300 |
| Power supply, Power
consumption |
100 - 240V, AC
50/60Hz, 250VA |
| Dimensions, Weight |
260 (W) x 600 (D)
x 280 (H) mm, about 11kg |
|
|
 |
 |
4. AQL-2120 Automatic Oil Evaporator |
| |
|
Based on azeotropic distillation method, moisture is separated from sample matrices and other interfering substances.
Sample changer holds up to 20 vials.
Exchanging the KF reagent can also be automated (Option).
Wide temperature setting (RT- 200 C) covers the full range of azeotropic points.
Reduces costs for KF reagent and waste disposal. |
|
| |
- Based on azeotropic distillation method, moisture is separated from sample matrices and other interfering substances.
- Sample changer holds up to 20 vials.
- Exchanging the KF reagent can also be automated (Option)
- Wide temperature setting (RT- 200 C) covers the full range of azeotropic points.
- Reduces costs for KF reagent and waste disposal.
|
|
 |
5. Special Sampling Devices |
 |
6. Other Options |
 |
| Model Name |
Description |
B-130-10
|
Additional Buret for
AQV-2100 series |
| PR-2000T2 |
Thermal Printer w/cable |
| PR-302B |
Dot Impact
Printer w/cable |
| K-2000A2 |
Magnetic Stirrer |
| K-2000A2P |
Magnetic Stirrer with
pump for solvent add/drain |
|
 |
| |
|
|
| To order titrators, related equipment, parts or accesories, please call, fax or email:
|
- Phone North America 1-800-495-1678
- Phone International 1-716-774-8706
- Fax 1-716-774-8708